Flow Meter Sensus

Flow Meter Sensus untuk Air Panas (Flow Meter Sensus for Hot Water)

WP-Dynamic 130°C
Flowsensor for hot water up to 130°C

Flow Meter Sensus WP-Dynamic counter is optimal for measurement of streaming high, relatively constant.

Special Features : 

  • Patented hydrodynamically  balanced rotor
  • Patented symmetric calibration adjustment
  • Sealed totalizer (IP 68)
  • Register may be rotate through 360
  • High overload cavability
  • Pattern approved removable measuring element
  • Up to 3 pulser (1xOD ; 2xRD) may be fitted without breaking the approval seal
  • Powder coating ensures maximum corrosion protection

Technical Data :

Meteran Air Plastik Westechaus

Body Material : Plastic (ABS)

Size : 15 mm

Max. Flow Rate : 3 m3/h

Weight : 0.5 kg

Nominal Flow Rite : 1.5 m3/h

Horizontal Water Meter Flange

Body Material : Cast Iron

Size : 50 – 400 mm

Max. Flow Rate : 30 – 2000 m3/h

Weight : 13.5 – 187 mm

Nominal Flow Rite : 15 – 1000 m3/h

Horizontal Flow Meter

Body Material : Cast Iron / Brass

Size : 15 – 50 mm

Max. Flow Rate : 3 – 30 m3/h

Weight : 1.6 – 8.2 kg

Nominal Flow Rite : 1.5 – 15 m3/h

Westechaus Flow Meter Air

Body Material : Cast Iron

Size : 15 – 25 mm

Max. Flow Rate : 3 – 7 m3/h

Weight : 1.6 – 2.7 kg

Nominal Flow Rite : 1.5 – 3.5 m3/h

Flow Meter Actaris Woltmag M

Nominal Diameter : 50 – 100 mm
Starting Flow Rate : 80 – 250 l/h
Max. Pressure : 20 bar
Max. Flow Rate : 30 – 150 m3/h
Max. Temperature : 50 degree C


Dimensions :

Nominal Diameter
mm
50
60/65
80
100
Inches
2″
2,5″
3″
4″
Pressure Version
Waltmag M
LP
HP
LP
HP
LP
HP
LP
HP
A
Standard *
mm
250
300
350
400
DIN
mm
270
-
300
360
B
mm
125
150
175
200
C
mm
125
150
175
200
D
mm
77.5
83
98
95
99
100
105,5
115
E
mm
184.5
215
225
255
225
225
259.5
265
F
mm
262
300
323
350
324
360
365
400
G
mm
165
185
200
228
H
mm
302.5
365
381
445
381
445
446
485
Weight (meter)
Kg
14.5
18
24.8
28.9
28
35
40.2
45.5
Weight (mechanism)
kg
3
3.8
5
5.4
5
5.4
6.6
7.3

Flow Meter Actaris Woltex

Nominal Diameter :50 – 500 mm
Starting Flow Rate : 0.19 – 20 m3/h
Max. Pressure : 20 bar
Max. Flow Rate : 50 – 5000 m3/h
Max. Temperature : 30 degree C

Dimensions :


Nominal Diameter (DN)

mm

Inches

50

2″

65

2,5″

80

3″

100

4″

125

5″

150

6″

200

8″

250

10″

300

12″

400

16″

500

20″

End Connection
Flange PN 10/16
Flange PN 10 or 16
A (Length) ISO
mm
200
200
200
250
250
300
350
450
500
600
800
A (Length) DIN
mm
200

200
225
250
-
300
350
-
-
-
-
A (Length) ISO long
mm
300
300
350
350
-
500
-
-
-
-
-
A (Length) AS (Australia/UK)
mm
311
-
413
-
-
-
-
-
-
-
-
B
mm
100
100
100
111
111
139
164
214
200
250
350
C
mm
100
100
100
139
139
161
186
236
300
350
450
D
mm
82,5
92,5
100
110
110
142,5
171
204
230
290
357,5
E
mm
160
160
160
169
169
194
220
195
342
342
342
F
mm
243
253
261
279
294
339
391
399
564
632
689
G
mm
165
185
200
220
220
285
340
405
460
580
715
H
mm
262
262
262
309
309
395
420
395
729
729
729
Weight
kg
3
3
3
5,4
5,4
7,8
8,5
8,5
54
54
54

Typical Performance :

Nominal Diameter (DN)

mm

Inches

50

2″

65

2,5″

80

3″

100

4″

125

5″

150

6″

200

8″

250

10″

300

12″

400

16″

500

20″

Starting Flow Rate
m3/h
0,19
0,22
0,3
0,38
0,4
1
1,6
3
10
15
20
Accuracy ±2% From
m3/h
0,4
0,6
1,2
1,5
1,5
3
3,5
5
15
30
40
Accuracy ±5% From
m3/h
0,35
0,5
0,75
0,9
1,2
1,5
2,5
3,5
12
25
30
Admissible peak flow (10′ max)
m3/h
90
200
250
300
300
700
1000
1500
2500
4500
7000
Max. admissible flowrate (continues)
m3/h
50
80
120
200
200
500
800
1200
2000
3000
5000
Head loss at Qmax
bar
0,2
0,5
0,55
0,23
0,23
0,15
0,12
0,12
0,2
0,17
0,3
Max. admissible temperature
°C
50
Max. admissible pressure
bar
20
Min. scale interval
L
0,5
5
50
Indicating range
m3
999999,99
9999999,9
99999999
Cyble HF pulse weight
L
10
100
1000

Flow Meter Actaris Multimag TM II

Nominal Diameter : 25 – 50 mm
Starting Flow Rate : 25 – 90 l/h
Max. Pressure : 10 bar
Max. Flow Rate : 7 – 30 m3/h
Max. Temperature : 0 to 30 degree C
Metrological Performances :
Nominal Diameter – DIN
mm
25
25
30
40
50 flanged
Inches
1″
1″
1¼”
1½”
2″
Starting Flow Rate
l/h
25
70
90
Minimum Scale Internal
l
0.05
0.5
Indicating Range
m3
9.999
99.999
Maximum Head Loss at Qmax
bar
0.42
0.45
0.45
0.7
0.9
Maximum Admissible Temperature
ºC
0 to 30
Maximum Admissible Pressure
bar
0,42
0,45
0,45
0.7
0.9
Maximum Flow Rate – Qmax
m3/h
7
10
10
20
30
Nominal or Permanent Flow Rate – Qt
m3/h
3.5
5
5
10
15
Transitional Flow Rate – Qt
m3/h
0.28
0.4
0.4
0.8
1.2
Minimum Flow Rate – Qt
m3/h
0.07
0.1
0.1
0.2
0.45
Pressure Loss Group at Qmax
bar
0.6
1

Water Flow Meter Actaris Multimag TM2

Nominal Diameter : 1/ 2 ” – 3/ 4 ” ( 15 – 20 mm )
Starting Flow Rate : 10 – 12 l/ h
Max. Pressure : 16 bar
Max. Flow Rate : 3 – 5 m3/ h
Max. Temperature : 40 degree C

Technical Characteristics :
Nominal Diameter (DN)

mm

pol

15

1/2″

20

3/4″

Length
mm
165/170/190
190
Metrology
Class
B
C
B
C
Typical Start Up
L/H
10
7
18
12
Minimum Flow Rate – Qmin
L/H
30
15
50
25
Transitional Flow Rate – Qt
L/H
120
22,5
200
37,5
Nominal Flow Rate – Qn
m3/h
1,5
1,5
2,5
2,5
Maxiumum Flow Rate – Qmax
m3/h
3
3
5
5
Maximum Temperature
°C
40
Maximum Temperature (<1h)
°C
50
Maximum Operating Pressure
bar
16
Head Loss at Qmax
bar
<1
Maximum Reading
m3
9,999 or 99,999
Minimum Reading
L
0,02

Flow Meter Actaris Flostar

Nominal Diameter : 1½ ” – 4 ”

Nominal Flow Rate : 11 – 55 m3/ h

Max. Pressure : 10 bar

Max. Flow Rate : 22 – 110 m3/ h

Max. Temperature : 30 degree C